LC-X7 Basic Serial Command Functional Specifications
9/24
6.8 INPUT 2 Command
COMMAND “C06” [CR]
Detail
Select Input 2
Note) When there is no board inserted to Input 2, it is not executed.
Acceptable [ACK] [CR]
Response
Unacceptable “?” [CR]
6.9 INPUT 3 Command
COMMAND “C07” [CR]
Detail
Select Input 3
Note) When there is no board inserted to Input 3, it is not executed.
Acceptable [ACK] [CR]
Response
Unacceptable “?” [CR]
6.10 INPUT 4 Command
COMMAND “C08” [CR]
Detail
Select Input 4
Note) When there is no board inserted to Input 4, it is not executed.
Acceptable [ACK] [CR]
Response
Unacceptable “?” [CR]
6.11 VIDEO MUTE ON Command
COMMAND “C0D” [CR]
Detail
Video Mute ON
This command works the same way as “SHUTTER” button of the remote control,
but it works only for Shutter Open, not for Shutter Close.
Acceptable [ACK] [CR]
Response
Unacceptable “?” [CR]
6.12 VIDEO MUTE OFF Command
COMMAND “C0E” [CR]
Detail
Video Mute OFF
This command works the same way as “SHUTTER” button of remote control, but
it works only for Shutter Close, not for Shutter Open.
Acceptable [ACK] [CR]
Response
Unacceptable “?” [CR]
6.13 REGULAR VIDEO IMAGE Command
COMMAND “C0F” [CR]
Detail Set screen size to Regular(4:3)
Acceptable [ACK] [CR]
Response
Unacceptable “?” [CR]