LC-X7 Basic Serial Command Functional Specifications
17/24
“10” [CR]
Status: Power Failure
When the power supply voltage inside the projector reaches abnormal level, the status
automatically moves to Power OFF.
Abnormal power supply voltage includes;
- Filter abnormal status
- Shutter abnormal status
The projector returns “10” [CR], which indicates the status moves to Power OFF due to
power failure. Fan also stops.
“28” [CR]
Status: Cooling Down due to Abnormal Temperature in process.
When the internal temperature rises abnormally, it automatically starts Cooling Down
process. Response value for this status is “28” [CR].
Even if the temperature comes down during this process, the given Cooling Down process
is executed and it moves to Standby mode.
“02” [CR]
Status: RS-232C Commands cannot be accepted
When receiving this response, re-send Status Read Command.
“24” [CR]
Status: Power Management Cooling Down in process.
When Power Management function in setting menu is set to ON, continuous 5 minutes of
no signal status leads to turning off lamps and starting Cooling Down operation (Green
LED on the projector body is turned off).
During this period, any Functional Execution Command cannot be accepted.
The Power Management Cooling Down operation continues about 90 seconds, then the
status moves to Power Management.
Status: No signal Power Management Cooling Down Power Management
Response: “00” 24 04
5 minutes of no signal status After about 90 sec.
“04” [CR]
Status: Power Management
This indicates it has moved to Power Management status according to the setting of Power
Management function in Setting menu.