LC-X7 Basic Serial Command Functional Specifications
7/24
6 Functional Execution Command
6.1 Format
1) PC issues a command in the format below:
“C” Command [CR]
Command: two characters (Refer to Functional Execution Command Table)
2) A projector decodes the received data and returns the result after getting ready to receive
another command.
[ACK] [CR]: (0x06, 0x0D) When the projector has received Functional Execution
Commands.
“?” [CR]: When the received data cannot be decoded
6.2 Command Pipelining
Functions which need command pipelining follow the rule below.
- Sender system issues any command every 100ms.
- When receiving the applicable command, the function is executed for 120ms from the
moment.
- When receiving the same command in succession within 120ms, the function is executed
for another 120ms from the moment.
- When there is no incoming command after 120ms, the execution of pipelining is stopped.
- When the projector receives incoming other command within 120ms, the execution of
pipelining is stopped.
6.3 Transfer Example
Changing input to INPUT3 with Basic Command.
Command
PC Projector “C” “0” “7” CR
Projector PC ACK CR
Processing
(a few ms 1s)