LC-X7 Basic Serial Command Functional Specifications
24/24
8.3 Status Read Command with Address
8.3.1 Format
1) PC issues a command in the format below:
“A” Address “CR” Command [CR]
or
“A” Address “CR” Command [CR]
Address: 3-digit number (“001”-“999”)
Command: String (Refer to Basic and Expand Serial Commands)
2) The only projectors that have the address matching with the one in the received data
decode the command, and it returns required data.
Required Data [CR]
Required Data: String (Refer to Basic Status Read Command Table)
*When the received data cannot to be decoded, the projector returns “?” [CR].