Eiki LC-X7 Manual de usuario Pagina 15

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 24
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 14
LC-X7 Basic Serial Command Functional Specifications
15/24
7 Status Read Command
7.1 Format
1) PC issues a command in the format below:
“CR” Command [CR]
Command: Single character (Refer to Status Read Command Table)
2) When a projector receives the appropriate command, it returns the required information as
a data string.
Required Data [CR]
Required Data: String (Refer to Status Read Command Table)
3) When the received data cannot be decoded, the projector returns “?” [CR].
7.2 Transfer Example
Get the selected input for the projector by Basic Commands.
Command (issue the current input read command)
PC Projector C” “R” “1” CR
Projector PC 1 CR
Response
(A few ms - 1s)
(Indicates Input 1 is selected)
Vista de pagina 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 23 24

Comentarios a estos manuales

Sin comentarios