LC_X80 Basic Serial Command Functional Specifications
22/23
7.4 Input Mode Read Command
Command
“CR1” [CR]
Detail Get currently selected Input No.
Acceptable “%1” [CR]
%1
”1” = Input 1 is selected.
“2” = Input 2 is selected.
“3” = Input 3 is selected.
“4” = Input 4 is selected.(only for Networking-capable models)
Response
Unacceptable
“?” [CR]
7.5 Lamp Time Read Command
Command
“CR3” [CR]
Detail
Get total lamp running hours.
*return lamp operating time multiplied by the given coefficient (not actual used
time)
Acceptable “%1” [CR]
%1
Display Lamp running hours with 5 digit numbers.
Example:
“00410” [CR] ---------- 410 hours
Response
Unacceptable
“?” [CR]
7.6 Setting Read Command
Command
“CR4” [CR]
Detail Get screen setting status such as Ceiling/Rear.
Acceptable “%1” [CR]
%1
“11” [CR] = Normal Screen Setting
“10” [CR] = Picture is top/bottom reversed. (Status: Rear & Ceiling
ON)
“01” [CR] = Picture is left/right reversed. (Status: Rear ON)
“00” [CR] = Picture is top/bottom and left/right reversed. (Status:
Ceiling ON)
Response
Unacceptable
“?” [CR]
7.7 Temp Read Command
Command
“CR6” [CR]
Detail
Get the information of temperature inside a projector.
With several built-in temperature sensors, it can get all the temperatures at once.
Acceptable “%1 _ %2 _ %3” [CR]
%1
%2
%3
%1 = Temp. of sensor 1
%2 = Temp. of sensor 2
%3 = Temp. of sensor 3
Temperature data basic format is “_00.0”. (“_” indicates a space)
When the temperature goes under 0, it starts with “-” instead of a
space like “-05.5” [CR].
When no temperature data returns due to hardware problems, it
starts with “E” like”E00.0” [CR].
With several built-in temperature sensors, the projector returns
the values in succession.
“_31.5_ _35.2_ 33.4 ” [CR]
The first sensor’s data is followed by one space and afterwards
the second sensor’s data.
Response
Unacceptable
“?” [CR]