Eiki LC-X80 Manual de usuario Pagina 13

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 23
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 12
LC_X80 Basic Serial Command Functional Specifications
13/23
6.27 POWER MANAGEMENT READY Command
Command
C2A[CR]
Detail
Set Power Management function to ready status
This status is stored in EEPROM and retained regardless of Power OFF/ON
operation.
Acceptable [ACK] [CR]
Response
Unacceptable
“?” [CR]
6.28 POWER MANAGEMENT CANCEL Command
Command
C2B” [CR]
Detail
Set Power Management function to off status
This status is stored in EEPROM and retained regardless of Power OFF/ON
operation.
Acceptable [ACK] [CR]
Response
Unacceptable
“?” [CR]
6.29 POWER MANAGEMENT SHUTDOWN Command
Command
C2E” [CR]
Detail
Set Power Management function to Shutdown mode.
This status is stored in EEPROM and retained regardless of Power OFF/ON
operation.
Acceptable [ACK] [CR]
Response
Unacceptable
“?” [CR]
6.30 D.ZOOM + Command
Command
C30 [CR]
Detail
Enter Digital Zoom mode and expand image size
This command works the same way as “D.ZOOM ” button of the remote control.
Acceptable [ACK] [CR]
Response
Unacceptable
“?” [CR]
6.31 D.ZOOM - Command
Command
C31 [CR]
Detail
Enter Digital Zoom mode and reduce image size
This command works the same as “D.ZOOM ” button of the remote control.
Acceptable [ACK] [CR]
Response
Unacceptable
“?” [CR]
6.32 INPUT 3 VIDEO Command
Command
C33 [CR]
Detail Select Video input in Input 3
Acceptable [ACK] [CR]
Response
Unacceptable
“?” [CR]
Vista de pagina 12
1 2 ... 8 9 10 11 12 13 14 15 16 17 18 ... 22 23

Comentarios a estos manuales

Sin comentarios