LC_XG400L Basic Serial Command Functional Specifications
14/24
6.29 ON START SET Command
Command “C28” [CR]
Detail
Enable Power ON Start
This status is stored in EEPROM and retained regardless of Power OFF/ON
operation.
Acceptable [ACK] [CR]
Response
Unacceptable “?” [CR]
6.30 ON START CANCEL Command
Command “C29” [CR]
Detail
Disable Power ON Start
This status is stored in EEPROM and retained regardless of Power OFF/ON
operation.
Acceptable [ACK] [CR]
Response
Unacceptable “?” [CR]
6.31 POWER MANAGEMENT READY Command
Command “C2A” [CR]
Detail
Set Power Management function to ready status
This status is stored in EEPROM and retained regardless of Power OFF/ON
operation.
Acceptable [ACK] [CR]
Response
Unacceptable “?” [CR]
6.32 POWER MANAGEMENT CANCEL Command
Command “C2B” [CR]
Detail
Set Power Management function to off status
This status is stored in EEPROM and retained regardless of Power OFF/ON
operation.
Acceptable [ACK] [CR]
Response
Unacceptable “?” [CR]
6.33 POWER MANAGEMENT SHUTDOWN Command
Command “C2E” [CR]
Detail
Set Power Management function to Shutdown mode.
This status is stored in EEPROM and retained regardless of Power OFF/ON
operation.
Acceptable [ACK] [CR]
Response
Unacceptable “?” [CR]
6.34 D.ZOOM + Command
Command “C30” [CR]
Detail
Enter Digital Zoom mode and expand image size
This command works the same way as “D.ZOOM ” button of the remote control.
Acceptable [ACK] [CR]
Response
Unacceptable “?” [CR]