LC-W4 Basic Serial Command Functional Specifications
7/25
6
Functional Execution Command
6.1 Format
6.1.1 PC issues a command in format as below:
“C” Command [CR]
Command: two characters (Refer to Functional Execution Command Table)
6.1.2 A projector changes the received data to decode and returns a result after being ready to
receive next command.
[ACK] [CR]: (0x06, 0x0D) When received Functional Execution Commands.
6.1.3 When the received data cannot be decoded, it returns “?” [CR]
6.2 Command Pipelining
When some functions (Volume +/-, Zoom +/-, etc.) need the command pipelining, the
performance is the same as that of the remote control.
6.2.1 System: issue any command every 100ms.
6.2.2 When receiving the appropriate command, the function is executed for 120ms from the
moment.
6.2.3 When receiving the same command continuously within 120ms, the function is executed for
another 120ms from the moment.
6.2.4 When there is no incoming command after 120ms, the execution of pipelining is stopped.
6.2.5 When the projector receives other incoming commands within 120ms, the execution of
pipelining is stopped.
6.3 Transfer Example
Change to video mode with Basic Command.
Command
PC ĺ Projector “C” “0” “7” CR
Projector ĺ PC ACK CR
Processing
(a few ms 5s)
Vista de pagina 6